System 2000 E Stop System
Checklist
  • Do you need 8, 16, 24 or 32 way of control?
  • If set-up is more then a 4-way do not forget to use the link cable supplied1
  • When a 12-way or more is required you will need a 20-way rack with mains distro
  • Do you have 32amp supply available and are the phases correct?
  • Do you need tails or splitter boxes?
  • Do you need additional hand controllers?
  • To reduce cables do you want to use multicore cables?
  • Do you need any motor cables
  • Do you need any other equipment?

 

Information

E Stop contactor removes overall power from motor power circuits, ensuring instant stop in critical circumstances.

DC control power is maintained, allowing identification of the E Stop station activated.

Regulations require an E Stop relay to Risk Level 3 for moving truss systems. These relays monitor the master E Stop contactor and verify that it is functioning before power can be applied to the system. System 2000 is equipped to Risk Level 4 throughout, including dual E Stop wiring circuits providing the highest safety levels available today.

 